首页    其他产品    Dual-Luciferase® Reporter Assay System(E1910)

Dual-Luciferase® Reporter Assay System(E1910)

货号:E1910
规格:100 assays
价格:1996 元
储存:-20℃储存

产品中心

  •  

    Sensitive, Rapid and Convenient Dual-Reporter Assay

    The Dual-Luciferase® Reporter (DLR™) Assay System provides an efficient means of performing two reporter assays. In the DLR™ Assay, the activities of firefly (Photinus pyralis) and Renilla (Renilla reniformis or sea pansy) luciferases are measured sequentially from a single sample.

    The firefly luciferase reporter is measured first by adding Luciferase Assay Reagent II (LAR II) to generate a luminescent signal lasting at least one minute. After quantifying the firefly luminescence, this reaction is quenched, and the Renilla luciferase reaction is initiated simultaneously by adding Stop & Glo® Reagent to the same sample. Both assays can be completed in about 4 seconds using a luminometer with reagent auto-injectors. In the DLR™ Assay System, both reporters yield linear assays with attomole (<10–18) sensitivities and no endogenous activity in the experimental host cells. Furthermore, the integrated format of the DLR™ Assay provides rapid quantitation of both reporters either in transfected cells or in cell-free transcription/translation reactions.

    For best results with the Dual-Luciferase® Assay, we recommend using a luminometer that has been validated for use with the assay. These luminometers are qualified as DLReady™. For a listing of qualified instruments, please visit the DLReady™ Validated Luminometers page.

    The pGL4 Luciferase Reporter Vectors are designed for use with the DLR™ Assay Systems. A Renilla luciferase vector with constitutive expression may be used in combination with any experimental firefly luciferase vector to co-transfect mammalian cells.

    Notice for Cat.# E1960 and E1980: Sufficient Passive Lysis Buffer is provided to perform 1,000 assays with cells grown in 96-well plates (typically 20μl of 1X PLB per well). For applications requiring more lysis reagent (e.g., >100μl/well), additional Passive Lysis Buffer may be purchased separately.

    Assay Advantages

    • Normalization to Renilla luciferase internal control allows more accurate results.
    • Samples don't have to be split, saving plates and time.
    • Allows study of weak promoters, low-level expression/regulation and expression in cells that transfect poorly.
    • Linear over 7 logs; very active samples typically do not need dilution.

     

    具体说明详见链接:Dual-Luciferase® Reporter Assay System (promega.com.cn)

  • 您还没有选择分类数据,请先选择数据
  • 我是段落。点击这儿添加你的文字并编辑它,非常容易。-双击进行编辑

浏览量:0